docs.unavlab.com

Main ❯ Underwater acoustic modems ❯ Modems comparison table

logo image
www.unavlab.com
support@unavlab.com
Modems comparison table

Modems comparison table

  uSwitch uWave uWave Max OEM uWave Max uWave USBL Modem
  image
Current status Available Available Available Available Available
Maximum communication range, m 3001 10001 30001,2 30001,2 30001,2
Data rate, bit/s 32 78 / 1563 / 3143 / 6343 78 / 1563 / 3143 / 6343 78 / 1563 / 3143 / 6343 78 / 1563 / 3143 / 6343
Dimensions, mm 100 x 19 x 25 (PCB)
Ø41 x 45 (transducer)
Ø41 x 45 80 x 43 x 29 (PCB)
Ø64 x 62 (transducer)
Ø64 x 62 Ø64 x 128
Weight (dry), g 30 (PCB)
150 (transducer)
160 54 (PCB)
360 (transducer)
360 440
Maximum operating depth, m 4004 300 400 / 1000 4,5 300 300
Supply voltage6, V 7 .. 13 5 .. 12 5 .. 12 5 .. 12 5 .. 12
Power consumption (RX/TX), W 0.36/24 0.33/6 0.33/15 0.33/15 0.33/15
Maximum acoustic source level (in band), dB re 1 μPa @ 1 m 165 169 175 175 175
Connection interface UART UART UART UART UART
Code division multiple access ✘ ✓ ✓ ✓ ✓
Logical addressing ✘ ✓ ✓ ✓ ✓
Packet mode with guaranteed delivery ✘ ✓ ✓ ✓ ✓
Propagation time measurement function ✓ ✓ ✓ ✓ ✓
Supply voltage measurement module ✘ ✓ ✓ ✓ ✘
Depth/temperature sensor ✘ ✓ ✘ ✓ ✓
Two-axis inclinometer ✘ ✘ ✘ ✘ ✓
Determination of the horizontal angle of arrival of the signal ✘ ✘ ✘ ✘ ✓

1 A parameter that determines the maximum range at which a signal can be received based on the electroacoustic parameters of the transmitter and receiver, spatial decrease in the intensity of sound energy, attenuation in the medium and underwater acoustic noise level.
2 When uWave Max OEM, uWave Max and uWave USBL Modem operate in any combination. The maximum communication range with standard uWave modems is 1000 meters. The parameter is specified for the standard data rate mode - 78 bit/s.
3 The standard data rate mode of 78 bit/s provides maximum communication range and noise immunity. Other modes are available by reflashing the devices.
4 The maximum depth is determined by the transducer. The modem’s printed circuit board must be located in the user’s one-atmosphere (normobaric) housing.
5 An operating depth of 1000 meters is achieved when using the RT-1.524525-1-FF transducer.
6 Maximum power and communication range are achieved at a supply voltage of 12 V.