Main ❯ Underwater acoustic modems ❯ uWave Max: Device specification
![]() |
![]() |
|---|---|
| www.unavlab.com support@unavlab.com |
uWave Max - underwater acoustic modem Device specification |
uWave Max provides underwater acoustic digital communication between 254 subscribers, using code mode, transparent channel mode or packet mode with logical addressing and guaranteed delivery. Extremely small size, low power consumption and ease of use make the uWave family modems an ideal solution for controlling autonomous underwater devices and transferring data in applications sensitive to size and weight.
The device allows you to:
uWave family devices use a simple NMEA-like protocol for configuration, and the supplied open-source libraries uWaveLib (.NET) and uWave ALibs (Arduino) make the integration of the modems into custom solutions as simple and fast as possible.
Differences from the base version of uWave:
* Patent RU2659299C1.
| PARAMETER | VALUE |
|---|---|
| DIMENSIONS (Ø x h) | 64 x 62 mm |
| WEIGHT (dry) | 0.36 kg |
| MAXIMUM DEPTH | 300 m |
| MAXIMUM ACOUSTIC COMMUNICATION RANGE1,8 | 3000 m |
| DATA RATE2 | 78/156/314/634 bit/s |
| POWER CONSUMPTION Rx/Tx | 0.33/15 W |
| SUPPLY VOLTAGE3,4 | 5 .. 12 V |
| DATA LINE VOLTAGE | 0 .. 3.3 V |
| DATA LINE OUTPUT IMPEDANCE | 1 kΩ |
| CARRIER | 20050 Hz |
| MAXIMUM ACOUSTIC SOURCE LEVEL (in band) | 175 dB re 1 μPa @ 1 m |
| BIT ERROR RATE | 10-6 |
| SNR5 | -2 dB |
| MAXIMUM RELATIVE VELOCITY | +/- 1 m/s |
| STARTUP TIME | 100 ms |
| OPERATING TEMPERATURE RANGE | -5 .. 50 °C |
| INTERFACE6 | UART 9600 bit/s |
| COMMUNICATION PROTOCOL | NMEA 0183 PUWV |
| CABLE LENGTH6 | 0.5 m |
| CABLE DIAMETER | 5 mm |
| MULTIPLE ACCESS SCHEME2 | 20 code channels |
| TRANSMITTER BUFFER SIZE | 127 bytes |
| COMMAND MODE | 16 preset messages (9 for user applications) |
| SIGNAL PROPAGATION TIME MEASUREMENT RESOLUTION7 | 0.0001 s |
| PACKET MODE | 254 addresses with delivery notification, broadcast messages, packet size up to 64 bytes |
| DEPTH SENSOR RESOLUTION (local)9 | 0.01 m |
| DEPTH SENSOR RESOLUTION (remote)9 | 0.1 m |
1 A parameter that determines the maximum range at which a signal can be received, based on the electro-acoustic parameters of the transmitter and receiver, the spatial decrease in the intensity of sound energy, attenuation in the medium and the level of underwater acoustic noise.
2 By default, the devices operate in the 78 bit/s data rate mode, which provides the maximum range, communication reliability and the maximum number of code channels. Different data rate modes are not compatible with each other. Switching the modem to another data rate mode is done by replacing its firmware.
3 The maximum output power is achieved when the modem is supplied with 12 V.
4 The device has built-in overvoltage protection of the amplifier circuit. At voltages above 12.8-13 volts, the device does not turn on the power amplifier, i.e. it does not allow data transmission.
5 The value was obtained in a laboratory static experiment, without taking into account the multipath propagation effect.
6 The value can be changed on request.
7 Given this value, the resolution when measuring distance, taking into account the speed of sound of 1500 m/s, is 0.15 m.
8 When working with another uWave Max, uWave Max OEM or when working with uWave USBL Modem modems. The maximum communication range with standard uWave modems is 1000 meters.
9 A modem equipped with a depth sensor can transmit depth readings locally - via the cable, to the control system, and remotely - upon request from another modem.