docs.unavlab.com

HomeOur educational projectsACubes A3R: Device Specification

logo image
www.unavlab.com
support@unavlab.com
ACubes A3R
Device specification

KEY FEATURES

DESCRIPTION

ACubes A3R is a single-frequency acoustic receiver module with logic output. A3R devices can be combined with the pulse transmitter A3T and share a single acoustic transceiving antenna. Devices can also be stacked up to 12 units, and each such stack can be combined with one transmitter. In this case, each receiver and transmitter uses a separate antenna.

The following antennas can be used:

TECHNICAL SPECIFICATIONS

PARAMETER VALUE
DIMENSIONS 100 x 50 x 10 mm
WEIGHT 0.015 kg
MAXIMUM ACOUSTIC COMMUNICATION RANGE1 300 m
POWER CONSUMPTION 20 mA
SUPPLY VOLTAGE 5 .. 15 V
DATA LINE VOLTAGE TTL/LVTTL (0 .. 3.3/0 .. 5) V
CARRIER FREQUENCY 25000 Hz
SIGNAL DETECTION LOCKOUT INTERVAL 100 ms
MAXIMUM RELATIVE VELOCITY +/- 2 m/s
OPERATING TEMPERATURE RANGE -5 .. 50 °C

1 Parameter defining the maximum range at which signal reception is possible, based on the electroacoustic parameters of the transmitter and receiver, spatial decay of sound energy intensity, medium attenuation, and ambient acoustic noise level.

PINOUT AND CONNECTION

image
A3R
pad layout and functions

CONNECTOR XS1

PIN NUMBER I/O FUNCTION
1 I Antenna input
2 - GND
3 - GND
4 I Connected to pin №1

CONNECTOR XS2

PIN NUMBER I/O ACTIVE STATE FUNCTION
1 - - GND
2 O 0 Transmission start strobe
3 - - GND
4 I 0 Pulse transmission trigger
5 - - GND
6 O 0 Receiver №1 strobe
7 - - GND
8 O 0 Receiver №2 strobe
9 - - GND
10 O 0 Receiver №3 strobe
11 - - GND
12 O 0 Receiver №4 strobe
13 - - GND
14 O 0 Receiver №5 strobe
15 - - GND
16 O 0 Receiver №6 strobe
17 - - GND
18 - - NC
19 - - GND
20 - - +Usupply

CONNECTOR XS3

PIN NUMBER I/O ACTIVE STATE FUNCTION
1 O 0 Common receiver strobe
2 - - GND
3 - - Reserved
4 - - GND
5 O 0 Receiver №7 strobe
6 - - GND
7 O 0 Receiver №8 strobe
8 - - GND
9 O 0 Receiver №9 strobe
10 - - GND
11 O 0 Receiver №10 strobe
12 - - GND
13 O 0 Receiver №11 strobe
14 - - GND
15 O 0 Receiver №12 strobe
16 - - GND
17 - - Reserved
18 - - GND
19 - - +Usupply
20 - - GND

CONNECTOR XS4

PIN NUMBER I/O FUNCTION
1 O Preamplifier output
2 O Connected to pin #1
3 - Reserved

CONNECTOR XP2

PIN NUMBER I/O FUNCTION
1 I 5 .. 15 V
2 - GND

SWITCHES (JUMPERS) P0 - P12

Switch P0 - Transponder Mode

The jumper connects pin 1 (Common receiver strobe) of connector XS3 and pin 4 (Pulse transmission trigger) of connector XS2. Thus, if the jumper is installed and the A3R module is paired with the A3T module, then upon receiving an acoustic signal, a response pulse transmission will be triggered.

Switch P0 controls enabling and disabling of the transponder mode for paired A3R and A3T modules.

Switches P1 - P12 - Bus Address

These switches allow routing the receiver strobe to a specified line of the bus formed by connectors XS2 and XS3. This function can be used when interfacing multiple receivers with individual receiving antennas to enable output of the signal from each receiver to different bus lines.