docs.unavlab.com

UCNL LLC


APPROVED
APPROVED
Head of R&D
UCNL LLC
Chief Engineer
UCNL LLC
_________________ A. V. Dikarev ________________ S. M. Dmitriev
"____" ______________ 20 ___
"____" ______________ 20 ___




PRODUCT PASSPORT
"Diver communication system"




1. GENERAL INFORMATION ABOUT THE PRODUCT

The system is designed for:

Voice messages are transmitted in half-duplex mode by means of acoustic waves propagating in water, using two types of devices: diver stations and surface communication stations. The diver stations are equipped with a button for switching between the “receive” and “transmit” modes and are attached to the tank. The devices are connected to the headset via a watertight connector. The headset contains a microphone and headphones (earphones). The diver stations have a one-piece, maintenance-free monoblock design and switch on upon contact with water. The internal power source is charged using the supplied charging chassis. The surface communication station is made as a plastic case; on its stainless steel front panel there are connectors for the supplied underwater acoustic transducer, the push-to-talk (PTT) handset (a microphone and a button for switching between the “receive” and “transmit” modes) and headphones, as well as the power toggle switch and the knob for volume level and communication channel selection. Both the surface and the diver stations can operate in only one of eight communication channels at a time. Switching between channels in the surface station is performed with the corresponding switch, and in the diver station with the supplied radio dongle using specialized software for a PC.

The maximum underwater acoustic communication range between the devices of the kit is 1000 m. The diver communication stations have a maximum immersion depth of 100 m.

Logos, information on the customer’s trademarks, design elements and inscriptions that do not affect the technical characteristics of the devices may be applied to the devices.

1.1. Specifications and documentation

Full technical specifications of the devices, user’s manuals and the e-mail address of technical support:

Technical documentation
website
Technical support
docs.unavlab.com support@unavlab.com

2. CERTIFICATE OF MANUFACTURE AND PACKING. DELIVERY SET. FACTORY NUMBERS.


Kit production date "___"______________ 20__
Packed and checked against the delivery set "___"______________ 20__
Packer _________________ / _________________

2.1. Location of factory numbers

The factory number is applied by hot stamping on the outer surfaces of the housings of the following devices:

No factory number is provided for the other components of the kit.

2.2. Delivery set contents

No. Name of the item in the delivery set Qty,
pcs
1 Surface station of the wireless voice communication system  
2 Charger of the surface station of the wireless voice communication system  
3 Underwater acoustic transducer of the surface station of the wireless voice communication system  
4 PTT handset of the surface station of the wireless voice communication system  
5 Audio adapter of the surface station of the wireless voice communication system  
     
6 Diver station of the wireless voice communication system  
7 Headset of the diver station of the wireless voice communication system  
8 Charger of the diver station of the wireless voice communication system  
9 Adapter for configuring the diver stations of the wireless voice communication system  

2.3. List of factory numbers of the items in the delivery set

No. Name of the item in the delivery set Factory number
1    
2    
3    
4    
5    
6    
7    
8    
9    
10    
11    
12    
13    
14    
15    
16    
17    
18    
19    
20    
21    
22    
23    
24    

3. MANUFACTURER’S WARRANTY. SERVICE LIFE

The warranty period for the supplied equipment kit is 24 (twenty-four) months and is counted from the date of actual receipt of the devices by the customer, unless otherwise provided by the contract. If, during the warranty period, defects or latent defects are found in the product (latent defects are defects that could not be detected during a check usual for the given product and were revealed only during operation), the Supplier shall eliminate them at its own expense by repairing the product or replacing it with a new one within a period of no more than 30 (thirty) calendar days and specified in the certificate of transfer of the product for repair. The warranty period for the product is extended by the time during which the product was not used because of the identified defects. The time during which the product was not used is counted from the date of the written notification to the Supplier of the identified defects until the day of receipt of the product under the acceptance certificate after repair (replacement). When the product is replaced, the warranty period for the product is counted anew from the date the parties sign the acceptance certificate after repair (replacement). Delivery of the product for replacement work from the Customer’s premises, and after the work has been completed to the Customer’s warehouse, is carried out using the Customer’s own resources.

The warranty obligations do not apply to the product in the case of:

4. NOTES ON OPERATION AND STORAGE

4.1. Interchangeability

Devices of the same type are fully interchangeable electrically.

4.2. Special storage requirements

The use of organic solvents and/or aggressive acids and/or alkalis to remove contamination from the surface of the devices and cables is not allowed.

4.3 Special safety precautions during operation

The devices are not rescue or human life-support equipment. Any work using the devices must be performed in strict compliance with the requirements of the intersectoral rules for diving/underwater operations, as well as the departmental and local regulations in force for the Customer governing diving operations.